Spacer shaft

DRY System
Purpose: to remove combustion products from the combustion site to the atmosphere
Fuels: liquid, gas or solid (excluding fuels with a sulfur content ≥ 0,2% by mass and solid fuels, excluding peat and coal)
System marking according to EN 1856-2
Ø 80-600 mm, T600-N1-D-Vm-L20 (050-100) -G
T600⁰ C-maximum operating temperature
N1- natural traction
D- dry operating conditions
Vm- corrosion resistant
G- resistant to soot ignition
Chimney - L20- stainless steel 1.4301
Ø - 80-200 mm - 0.5; 0.6; 0.8, 1.0 mm
Ø - 250-550 mm - 0.6; 0.8, 1.0 mm
Ø - 600 mm -0.8; 1.0 mm
WET system
Purpose: to remove combustion products from the combustion site to the atmosphere
Fuel: liquid, gas or solid fuel
System marking according to EN 1856-2
Ø 80-600 mm, T600-N1-W-Vm-L50 (050-100) -G
T600⁰ C-maximum operating temperature
N1- natural traction
W- for operation in wet conditions
Vm- corrosion resistant
G- resistant to soot ignition
Chimney -L50- stainless steel 1.4404
Ø - 80-200 mm - 0.5; 0.6; 0.8, 1.0 mm
Ø - 250-550 mm - 0.6; 0.8, 1.0 mm
Ø - 600 mm -0.8; 1.0 mm