FoxESS T10-G3
New product
Power: 10 kW
Phase: Three-phase
Weight: 17.0 kg
MPPT Connectors: 2
Warranty: 12 years
Fox ESS - reliable and efficient inverters that can significantly reduce your electricity costs and increase your home's energy independence. These inverters are highly attractive due to their high quality, reliability, and exceptional performance.
The main benefit of Fox ESS inverters is the ability to efficiently regulate the supply and consumption of electricity. These inverters are manufactured using modern, advanced technologies and maximize the utilization of energy generated from renewable sources such as solar panels or wind turbines.
Another important advantage of Fox ESS inverters is their ease of use and management. They feature an advanced control interface that allows for easy monitoring and control of your energy usage and setting priorities for energy supply.
By reducing dependence on traditional electricity sources and increasing the utilization of renewable energy sources, Fox ESS inverters contribute to environmental protection and sustainable energy consumption.
Fox ESS is a high-quality, reliable, and innovative inverter that allows you to save money, achieve greater energy independence, and contribute to a sustainable future for the environment.
TECHNICAL SPECIFICATIONS | |||||||||
MODEL | T3-G3 | T5-G3 | T8-G3 | T10-G3 | T12-G3 | T15-G3 | |||
INPUT | |||||||||
Max. Recommended DC power [W] | 4500 | 7500 | 12000 | 15000 | 18000 | 22500 | |||
Max. DC Voltage [V] | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | |||
Nominal DC Opera ng Voltage [V] | 600 | 600 | 600 | 600 | 600 | 600 | |||
Max. Input Current (input A/input B) [A] | 14/14 | 14/14 | 14/14 | 14/14 | 14/14 | 28/28 | |||
Max. Short Circuit Current (input A/input B) [A] | 18.2/18.2 | 18.2/18.2 | 18.2/18.2 | 18.2/18.2 | 18.2/18.2 | 36.4/36.4 | |||
MPPT Voltage Range [Vdc] | 140-1000 | 140-1000 | 140-1000 | 140-1000 | 140-1000 | 140-1000 | |||
MPPT Voltage Range (full load) [Vdc] | 140-850 | 190-850 | 300-850 | 380-850 | 455-850 | 275-850 | |||
Start-up voltage [V] | 140 | 140 | 140 | 140 | 140 | 140 | |||
No. of MPP Trackers | 2 | 2 | 2 | 2 | 2 | 2 | |||
Strings per MPP Tracker | 1+1 | 1+1 | 1+1 | 1+1 | 1+1 | 2+2 | |||
OUTPUT | |||||||||
Nominal AC Power [W] | 3000 | 5000 | 8000 | 10000 | 12000 | 15000 | |||
Max. Apparent AC Power [VA] | 3000 | 5000 | 8000 | 10000 | 12000 | 15000 | |||
Rated Grid Voltage (AC Voltage Range) [Vac] | 3/N/PE, 220V/380V, 230V/400V 240V/415V | ||||||||
Rated Grid Frequency [Hz] | 50/60 | ||||||||
Nominal AC Current [A] | 4.3 | 7.2 | 11.6 | 14.5 | 17.4 | 21.7 | |||
Max. AC Current [A] | 4.8 | 8.0 | 12.8 | 15.9 | 19.1 | 23.9 | |||
Displacement Power Factor | 1 (Adjustable from 0.8 leading to 0.8 lagging) | ||||||||
Total Harmonic Distor on (THDi, @rated output) | <3% | ||||||||
EFFICIENCY | |||||||||
MPPT Efficiency [%] | 99.8 | ||||||||
Euro Efficiency [%] | 97.8 | ||||||||
Max. Efficiency (@rated voltage) [%] | 98.6 | ||||||||
PROTECTION | |||||||||
DC Reverse-polarity Protec on: | YES | ||||||||
An -islanding Protec on: | YES | ||||||||
Insula on Monitoring: | YES | ||||||||
Residual Current Monitoring: | YES | ||||||||
AC Short Circuit Protec on: | YES | ||||||||
AC Output Over Current Protec on: | YES | ||||||||
AC Output Over Voltage Protec on: | YES | ||||||||
Surge Protec on: | Type II(DC) / Type II(AC) | ||||||||
Temperature Protec on: | YES | ||||||||
Integrated DC Switch: | YES | ||||||||
AFCI Protec on | Op onal | ||||||||
String Level Monitor | |||||||||
STANDARD | |||||||||
Safety | IEC62109-1/2 | ||||||||
EMC | IEC 61000-6-1/IEC 61000-6-2/IEC 61000-6-3/IEC61000-4-2/3/4/5/6/8 | ||||||||
AS4777.2-2020 / VDE-AR-N 4105 /VDE0126-1-1 /G98 / G99 / EN50549-1/ CEI 0-21/ NB/T32004 | |||||||||
Cer fica on | IEC62116 /IEC61727 /IEC61683 | ||||||||
GENERAL DATA | |||||||||
Dimensions (WxHxD) [mm] | 370*480*183.5 | ||||||||
NET Weight [kg] | 17 | ||||||||
Cooling Concept | Natural | ||||||||
Protec ve class | Ⅰ | ||||||||
Degree of Protec on (according to IEC60529) | IP65 | ||||||||
Topology | Transformerless | ||||||||
Over Voltage Category | III (AC side), II (PV side) | ||||||||
Noise [dB] | <30 | ||||||||
Opera ng Temperature Range [°C] | -25…... +60(dera ng at +45) | ||||||||
Storage Temperature Range [°C] | -40…... +70 | ||||||||
Al tude[m] | 3000 | ||||||||
Humidity | 0-100% (no condensa on) | ||||||||
Self Consump on (night) [W] | <3 | ||||||||
Pollu on Degree | Ⅱ | ||||||||
Monitoring Module (op onal) | RS485, WIFI (op onal) / GPRS (op onal) / 4G(op onal) | ||||||||
Communica on | Meter, DRM, USB update, E-stop | ||||||||
Display | LCD screen, Touch Key, App, Website |